A.1.5 Comparison of Functions of WJ200 and WJ-C1
WJ200 and WJ-C1 have the same parameter system, but there are functions that have changed
in operation.
For details, refer to the table below and the corresponding part in the "Page" column.
Change from WJ200 to WJ-C1
WJ-C1 cannot start running if "Free-V/f frequency 7 [b112]" is set to less than 30 Hz.
Free-V/f frequency 6 to 400 (Hz)
Free-V/f frequency 6 to 590 (Hz)
* Cannot start running if the
setting value is less than 30 Hz.
Control with
a speed
sensor
Speed detection method at inputting single-phase pulse ([EA]/PLA)) has been changed
as follows.
Single-phase pulse input (A phase)
EA (A phase): 32 kHz max.
EB (B phase): 1.8 kHz max.
Single-phase pulse input (A phase)
PLA (A phase): 32 kHz max.
PLB (B phase): 32 kHz max.
Positioning
restart
function
The operation of the positioning for the positioning restart function has been changed as
follows.
Automatic carrier frequency reduction by DC braking force has been changed as follows.
Carrier frequency during
DC braking (kHz)
Carrier frequency during
DC braking (kHz)
When [JG] is ON while [FW] is ON, decelerate to the jogging frequency as follows.
A selection of the "Soft-Lock selection [b031]" becomes invalid as follows.
10: High level access
including b031