22 23
Optima and Minima Series Receiver Link (ID-Setting or Bind) cont.
When the binding is process is completed, it
automatically goes to the nish screen. (The
BLUE and RED LEDs will be solidly on)
When the LED stops blinking, press the jog
dial to get to the next screen. The blue LED
will glow solid.
Turn the power to the receiver o, then back on. Check for a solid blue LED light. If it appears then press the
jog dial to FINISH the binding process. Make sure all functions are working properly before ying your model.
If any function is not working as described, please go back to step 6 and repeat the
binding again.
If all functions work well press the Finish icon on the screen to nish binding
FAIL-SAFE and Hold Mode Setup
If the FAIL SAFE function is set up and used properly but the receiver signal is somehow interrupted,
the servos will move to your previously stored FAIL-SAFE setup. If you do not activate the FAIL-SAFE
function, the signal is switched o after the HOLD period of 1 sec. This means that the servos become
“soft” and remain in their last commanded position under no load (this may equate to full-throttle!), until
a valid signal is picked up again. In the interests of safety, we recommend that FAIL-SAFE should always
be activated, and the FAIL-SAFE settings should be selected so as to bring the model to a non-critical
situation (e.g. motor idle / electric motor OFF, control surfaces neutral, airbrakes extended, aero-tow
release open, etc.).
Testing the FAIL-SAFE Setting
Move the sticks to positions other than the FAIL-SAFE settings, and then switch o the transmitter. The
servos should now move to the FAIL-SAFE positions previously stored, after the one second HOLD period.
How to turn FAIL-SAFE O and reactivate the Hold Mode
a. Switch on the transmitter, then the receiver. Wait for the system to boot and you have control over the
model.
b. Press and hold the receiver function button for 6 seconds and release it. After 2 seconds the red and
blue LEDs will blink rapidly.
c. Immediately press the button once.
d. FAIL-SAFE Mode is now deactivated and HOLD mode is activated.
e. Turn the transmitter o, then the receiver o.
f. Turn the system back on to use it.