Maintenance
8500C/8500C+ System Maintenance Manual A-17
900±1 RPM
0.4±0.04 IPS
275°±10°
cc. Press STOP key.
cd. Disconnect cable #4 FWD COMP from Velocimeter and connect #1 PROP cable.
ce. Press SETUP key.
cf. Select INPUT field with arrow keys.
cg. Key in 5 with numeric key for #1 PROP cable.
ch. Press ENTER soft key.
ci. Wait 10 seconds.
cj. Press START key.
ck. Verify that display indicates:
900±1 RPM
0.4±0.04 IPS
275°±10°
cl. Press STOP key.
cm. Move cable P/N 11517 to connector labeled “13-20” on 8520C-36 and move magnetic
pickup cable #10808 to channel B on 8520C-36. Repeat Steps f through cl, but when the
steps call for you to enter pickup and channel information in the setup screen, substitute
the following values:
PICKUP: CHANNEL S<B>
#A1: CHANNEL 19
#A2: CHANNEL 18
#3 ENG. ACC: CHANNEL 15
#2 AFT G/B: CHANNEL 14
#5 ENG COOD: CHANNEL 17
#4 FWD COMP: CHANNEL 16
#1 PROP: CHANNEL 13
cn. Move cable P/N 11517 to connector labeled “21-28” on 8520C-36 and move magnetic
pickup cable #10808 to channel C on 8520C-36. Repeat steps f through cl, using the
following values:
PICKUP: CHANNEL <C>
#A1: CHANNEL 27
#A2: CHANNEL 26
#3 ENG. ACC: CHANNEL 23
#2 AFT G/B: CHANNEL 22

Table of Contents