GasAlertMaxXT II
User Manual
66
Specifications
Instrument dimensions: 13.1 x 7.0 x 5.2 cm (5.1 x 2.8 x 2.0 in.)
Weight: 328 g (11.6 oz.)
Operating temperature: -20°C to +50°C (-4°F to +122°F)
Storage temperature: -40°C to +60°C (-40°F to +140°F)
Operating humidity: 10% to 100% relative humidity (non-condensing)
Dust and moisture ingress: IP66/67
Alarm setpoints: May vary by region and are user-defined
Detection range:
H
2
S: 0 – 200 ppm (1 ppm increments)
CO: 0 – 1000 ppm (1 ppm increments)
O
2
: 0 – 30.0% vol. (0.1% vol. increments)
LEL (combustible): 0 – 100% LEL (1% LEL increments) or
0 – 5.0% v/v methane
Sensor type:
H
2
S, CO, O
2
: Single plug-in electrochemical cell
LEL (combustibles): Plug-in catalytic bead
O
2
measuring principle: Capillary controlled concentration sensor
Alarm conditions: TWA alarm, STEL alarm, low alarm, high alarm,
multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence
beep, automatic deactivation alarm, pump alarm
Audible alarm: 95 dB+ at 30 cm variable pulsed beeper with full battery
charge
Visual alarm: Red light-emitting diodes (LEDs)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Activates upon startup and when the pushbutton is pressed;
deactivates after 10 seconds. Activates during an alarm condition and
remains lit until alarm ceases
Self-test: Initiated during activation, self-test runs continuously while
detector is operational
Calibration: Automatic zero and automatic span
User field options: Startup message, lockout on self-test error, safe
mode, confidence beep, latching alarm, force calibration, cal IR lock,
force bump, location logging, force block test, set datalog interval, set
confidence interval, language selection.
Sensor options: Sensor enable/disable, set span concentration values,
set calibration interval, set bump interval, set alarm setpoints, set STEL
interval, set TWA period, auto zero at startup enable/disable, 5% over-
span, low alarm acknowledge, oxygen measurement, and combustible
gas measurement
Maximum hose length for sampling: 75 ft (22 m)
Maximum hose length for calibration: 3 ft (0.9 m)
Battery operating time: One rechargeable lithium polymer battery at
20°C provides 13 hours operating runtime
Year of manufacture: The detector’s year of manufacture is determined
from the serial number. The first and second number after the first two
letters determines the year of manufacture.
Example: MA110
-001000 = 2010 year of manufacture

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell GasAlert Max XT II and is the answer not in the manual?

Honeywell GasAlert Max XT II Specifications

General IconGeneral
BrandHoneywell
ModelGasAlert Max XT II
CategorySecurity Sensors
LanguageEnglish

Related product manuals