Event Logs
The detector records the thirty most recent gas alarm events.
Information that is recorded from an event is as follows:
Serial number of the detector
Start time of alarm
Type, level, and duration of alarm
Status of sensor
Peak exposure level (ppm or %)
Status of the detector
Detector user
Supervisor
•Location
Definables (employee information)
Datalogs
The detector records datalog samples that can be compiled to create a
report using Fleet Manager II. From Fleet Manager II, define how often
the detector records a datalog sample (1-120 seconds) in the Datalog
Interval (seconds) field.
The detector is capable of storing 6 hours to 5 years of information,
depending upon the datalog interval and what information is stored.
When the memory is full, the detector replaces the oldest datalogs with
the most recent datalogs.
The following information is recorded in a datalog:
Serial number of the detector
Date and time
Type of datalog
Detector status
Detector user
Type of gases the detector monitors
Gas readings
STEL and TWA readings (H
2
S and CO only)
Alarm setpoints
Options enabled/disabled
Sensor status
Pump status
Logging intervals
Language detector is set to display
Calibrations performed
Bump tests performed
Battery readings
Temperature readings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell GasAlert Max XT II and is the answer not in the manual?

Honeywell GasAlert Max XT II Specifications

General IconGeneral
BrandHoneywell
ModelGasAlert Max XT II
CategorySecurity Sensors
LanguageEnglish

Related product manuals