Table 20 Abnormal Alarm Parameters 
Parameter  Description 
Enable abnormal events  Check the box    to enable the function. 
Abnormal type  Disk alarm, IP address conflict, network disconnect 
Event actions  Enable different event actions 
1.  Click APPLY to complete settings. 
Alarm Out 
The external alarm device is connected to the alarm out port. 
1.  Go to Main Menu > Event > Alarm out. 
The Alarm Out interface is displayed. 
Figure 72 Alarm Out 
 
2.  Configure parameters. 
Table 21 Alarm Out Parameters 
Parameter  Description 
Port number  Correspond to real panel I/O port OUT 1 
Port name   
Input the port name. The name will show on the alarm information 
message. 
Valid signal   
Close: An alarm is generated when an external alarm signal is 
received. 
Open: An alarm is generated when no external alarm signal is 
received. 
Alarm output mode 
When the device receives I/O alarm signals, the device sends the 
alarm information to an external alarm device 
3.  Click APPLY to complete settings.