EasyManua.ls Logo

Honeywell HRHD4+ - System Check Screen; Storage Screen

Honeywell HRHD4+
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Rev 3.01 32 Document 900.0258
10/05
System Check Screen
Use the System Check screen to check the status (fault condition) of the DVR. Highlight
System Check in the System menu (MENU
System System Check) and then
press # . The System Check setup screen displays.
Figure 3-12 System Check Screen
1. Highlight the box under the On/Off heading and then press # . This toggles
between On and Off.
When it is On, the DVR reports a fault condition if it does not detect any recording
or if there is an alarm during the designated time.
2. Highlight the box under the Interval heading and then press # . A slide bar
displays allowing you to set the check interval from 1 Hour to 30 Days by using
the Left and Right Arrow buttons.
3. The Status field displays the fault conditions.
Good means that there was recording or an alarm occurred during the
designated time.
Bad indicates that there was no recording or no alarm occurred during the
designated time.
Storage Screen
Highlight Storage in the System menu (MENU System Storage) and then press
# . The Storage setup screen displays.
The DVR displays the storage status when the installed IDE hard disk drives support the
S.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology) monitoring program.

Table of Contents

Other manuals for Honeywell HRHD4+

Related product manuals