19
RSS BAR CODE IMPLEMENTATION 
 
Metrologic’s MS9520 Voyager
®
 and MS9540 VoyagerCG
®
 laser scanners with 
software #14810 and higher can be configured to scan RSS type codes. 
 
XT keyboard will no longer be supported in standard software releases 
with software #14810 or higher.  If XT keyboard is needed for your 
application, software #14806 or lower is required, contact a Metrologic 
customer service representative at 1-800-ID-METRO for further 
assistance. 
 
³100011
 
Double Border Required - When scanning RSS 
bar codes, it is recommended that double border 
requirements be enabled because of the large 
spaces often found in RSS symbologies. 
³100413
 
Enable RSS 14 
³100403
 
*  Disable RSS 14 
³114900
 
*  Transmit RSS 14 Check Digit 
³114910
 
Do Not Transmit RSS 14 Check Digit 
³114901
 
*  Transmit RSS 14 Application ID - Application 
Identifier “01” is transmitted by default. 
³114911
 
Do Not Transmit RSS 14 Application ID 
³114902
 
*  Transmit RSS 14 Symbology ID - Symbology 
Identifier “]e0” is transmitted by default. 
³114912
 
Do Not Transmit RSS 14 Symbology