33
SCANNER OPERATION 
 
HOST SCANNER COMMANDS 
 
³118015
 
Enable D/E Disable Command. - The scanner will 
disable scanning after it receives an ASCII “D” from 
the host device.  It will enable scanning when it 
receives an ASCII “E”. 
³118005
 
*  Disable D/E Disable. 
³118211
 
Enable Z/R Type D/E Simulation - The scanner 
will disable scanning after it receives an ASCII “Z” 
from the host device. It will enable scanning when it 
receives an ASCII “R”. 
³118201
 
*  No Z/R Type D/E Simulation 
³118014
 
Enable F/L Laser Command - The scanner will 
turn off the laser after the scanner receives an 
ASCII “F” character.  The laser will turn on after it 
receives an ASCII “L” character. 
³118004
 
*  Disable F/L Laser Command 
³118115
 
Use DTR Scan Disable - The scanner will monitor 
the DTR input to determine if scanning should be 
allowed.  A +12V “active” level enables decoding.  
A -12V “inactive” level disables decoding. 
³118105
 
*  Do Not Use DTR Scan Disable - Do not monitor 
the DTR input. 
³118110
 
Activate DC2 Character - Scanning will be initiated 
with the receipt of a DC2 character (^R, 124). 
³118100
 
*  Do Not Activate on DC2 Character 
³115917
 
Transmit “METROLOGIC” with receipt of an “I” 
(49H) via RS232 
³115907
 
*  Don’t Transmit “METROLOGIC” with receipt of 
an “I” (49H) via RS232