25
COMMUNICATIONS
³415524
Enable Light Pen/Wand Communication - Use
this option if scanner should be used in place of a
light pen.
³415554
* Enable RS232 - The scanner will work with
RS232 +/- 12V serial output.
³999994
Load Keyboard Wedge Defaults - Scan this code
before selecting Normal or Stand Alone Wedge
Mode.
³5155153
Enable Stand-Alone Keyboard Scanner - Allows
scanner to be used without an external keyboard.
³5155143
Enable Keyboard Wedge Emulation - Select if
the scanner provides keyboard emulation by
converting the scanned bar code data to the PC
keyboard scan code equivalent.
³999993
Load OCIA Defaults - Scan this code before
selecting Enable OCIA output.
³415544
Enable OCIA Output - Select this option if the
communications requirement is on Optically
Coupled Interface Adapter (OCIA). This is a
docked (by the host) serial interface.
³999995
Load IBM 46xx Defaults
³415504
Enable IBM 46xx Communication - Select this
option for IBM 46xx SIOC/RS485 communications.
Not all scanners support this interface. The correct
interface board is required.
³415534
Enable No Communication Mode - Select this
option if the scanner does not interface with the
host device.
³917500
Reserved
³415564
Reserved

Table of Contents