25
 COMMUNICATIONS  
 
³415524
 
Enable Light Pen/Wand Communication - Use 
this option if scanner should be used in place of a 
light pen. 
³415554
 
* Enable RS232 - The scanner will work with  
RS232 +/- 12V serial output. 
³999994
 
Load Keyboard Wedge Defaults - Scan this code 
before selecting Normal or Stand Alone Wedge 
Mode. 
³5155153
Enable Stand-Alone Keyboard Scanner - Allows 
scanner to be used without an external keyboard. 
³5155143
Enable Keyboard Wedge Emulation - Select if 
the scanner provides keyboard emulation by 
converting the scanned bar code data to the PC 
keyboard scan code equivalent. 
³999993
 
Load OCIA Defaults - Scan this code before 
selecting Enable OCIA output. 
³415544
 
Enable OCIA Output - Select this option if the 
communications requirement is on Optically 
Coupled Interface Adapter (OCIA).  This is a 
docked (by the host) serial interface. 
³999995
 
Load IBM 46xx Defaults 
 
³415504
 
Enable IBM 46xx Communication - Select this 
option for IBM 46xx SIOC/RS485 communications. 
Not all scanners support this interface.  The correct 
interface board is required. 
³415534
 
Enable No Communication Mode - Select this 
option if the scanner does not interface with the 
host device. 
³917500
 
Reserved 
³415564
 
Reserved