23
ISBT CODE 128 IMPLEMENTATION
PRE-DEFINED CONCATENATION CONFIGURATION MODE BAR CODES
³4384100
Donation Identification Number + Confidential
Unit Exclusion Status =á + &! Concatenation
³4384110
Product Code + Expiration Date (Form 1)
=< + =>Concatenation
³4384120
Product Code + Expiration Date (Form 2)
=< + &> Concatenation
³4384130
Product Code + Expiration Date (Form 3)
&< + => Concatenation
³4384140
Product Code + Expiration Date (Form 4)
&< + &> Concatenation
U
SER-DEFINED CONCATENATION CONFIGURATION MODE BAR CODES
Supported by the MS9500 series only.
The first two bar codes can be used to enable/disable user-defined
concatenation sequences. The remaining bar codes are used to enter the user-
defined identifiers used in the concatenation sequence. These bar codes require
that the user enter configuration mode first. Then, after scanning the appropriate
code, follow the rules for using code bytes to enter the desired identifiers.
³138414
Enable User-Defined Sequences
³138404
Disable User-Defined Sequences
³938000
1
st
Left Identifier
³938100
2
nd
Left Identifier
³938200
1
st
Right Identifier
³938300
2
nd
Right Identifier