30
SCANNER OPERATION
BEEPER OPTIONS
³118417
Beep on BEL Command - The scanner beeps
when it receives a BEL character from the host. If
a number is sent within 200 msecs before the BEL
character, the scanner will beep that number of
times.
³118407
* Ignore BEL Command
³116913
Enable Light Pen Toggle During Beep - The
scanner beeps and toggles the light pen data line
on a successful decode. This drives a good read
indicator.
³116903
* Disable Light Pen Toggle During Beep
³124711
Enable Pass-Through
³124701
Disable Pass-Through
³125011
Beep with Pass-Through Data
³125001
* No Beep with Pass-Through Data
³125010
Enable Record Count Capture
³125000
* No Record Count Capture
³998052
Transmit Record Counts