53
RS232
HARDWARE HANDSHAKING
³124510
Invert RTS Polarity (RSV1)
-12V = Active +12V = Inactive
³124500
* Standard RTS Polarity - Use standard RTS polarity
-12V = Inactive +12V = Active
³124511
Invert CTS Polarity (RSV2)
-12V = Active, +12V = Inactive,
OK to send Do not send
³124501
* Standard CTS Polarity
-12V = Inactive, +12V = Active,
Do not send OK to send
³124512
Activate RTS, Do Not Wait for CTS (RSV3) -
Activate RTS for transmission but do not wait for
CTS to send.
³124502
* Activate RTS, Wait for CTS - Wait for CTS after
activating RTS.
³124513
Test CTS Not Present Before RTS (RSV4) - Do
not activate RTS if CTS is already present.
³124503
* Do Not Test for CTS Present Before RTS
³115817
Enable DTR Support - The scanner will stop
scanning when the Data Terminal Ready (DTR)
signal goes inactive.
³115807
* Disable DTR Support
³115915
Enable RTS Counter Toggle - The scanner will
toggle the RTS line on a good decode.
³115905
* Disable RTS Counter Toggle
³115914
Enable XON/XOFF Handshaking - The scanner
will stop transmission whenever on XOFF
(ASCII 13H) is received. Transmission will resume
after an XON (ASCII 11H) is received.
³115904
* Disable XON/XOFF Handshaking.