OCR Symbology
Font Font selection:
Disabled
A = OCR A
B = OCR B
Money = OCR Money
MICR = Magnetic Ink Character Recognition
Default is disabled.
Direction Decoder reads OCR fonts in any direction, but setting direction
parameter correctly can increase decoding speed:
Left to Right
Top to Bottom
Right to Left
Bottom to Top
Default is Left to Right.
Template Template length must match the length of OCR string to be read.
Valid template selections are:
a - alphanumeric character (digit or letter)
c - check character
d - digits from 0 to 9
e - any character
g - any character specified in group G
h - any character specified in group H
l - alphabetic letter
r - delimits a row
t - delimits multiple templates
All characters are transmitted as is except for the selected template. Default is
dddddddd.
Group G Null terminated string defines the set of characters in group G. The
default is null.
Group H Null terminated string defines the set of characters in group H. The
default is null.
Check Enter the string constant 0123456789 for modulo10 checksums and
the string constant 0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ for
modulo36 checksums.
The default is null.