Parameter Default Function
Frag
Thresh
2346
If the packet size (in bytes) exceeds the specified number of bytes set in the fragment threshold, the
packet is fragmented (sent as several pieces instead of as one block). Use a low setting in areas
where communication is poor or where there is a great deal of wireless interference.
Options are: Any number between 256 bytes and 2346 bytes.
RTS
Thresh
2347
If the packet size exceeds the specified number of bytes set in the Request to Send (RTS) threshold,
an RTS is sent before sending the packet. A low RTS threshold setting can be useful in areas where
many client devices are associating with the Access Point.
Options are: Any number between 0 and 2347.
LED Off
The LED on the wireless card is not visible to the user when the wireless card is installed in a sealed
mobile device.
Options are: On, Off.
Tray Icon On
Determines if the Summit icon is displayed in the System tray.
Options are: On, Off
Hide
Password
On
When On, the Summit Config Utility masks passwords (characters on the screen are displayed as an
*) as they are typed and when they are viewed. When Off, password characters are not masked.
Options are: On, Off.
Admin
Password
SUMMIT
(or
Blank)
A string of up to 64 alphanumeric characters that must be entered when the Admin Login button is
tapped. If Hide Password is On, the password is masked when typed in the Admin Password Entry
dialog box. The password is case sensitive. This value is masked when the Admin is logged out.
Options are: none.
Auth
Timeout
8
seconds
Specifies the number of seconds the Summit software waits for an EAP authentication request to
succeed or fail.
If the authentication credentials are stored in the active profile and the authentication times out, the
association fails. No error message or prompting for corrected credentials is displayed.
If the authentication credentials are not stored in the active profile and the authentication times out,
the user is again prompted to enter the credentials.
Options are: An integer from 3 to 60.
Certs Path System
A valid directory path, of up to 64 characters, where WPA Certificate Authority and User Certificates
are stored on the mobile device when not using the Windows certifcates store. The Windows folder
must exist before assigning the path in this parameter. See Certificates for instructions on obtaining
CA and User Certificates.
Options are: none.
For example, when the valid certificate is stored as My Computer/System/MYCERTIFICATE.CER,
enter System in the Certs Path text box as the Windows folder path.
Ping
Payload
32 bytes
Maximum amount of data to be transmitted on a ping.
Options are: 32 bytes, 64, 128, 256, 512, or 1024 bytes.
Ping
Timeout
ms
5000
The amount of time, in milliseconds, that a device will be continuously pinged. The Stop Ping button
can be tapped to end the ping process ahead of the ping timeout.
Options are: Any number between 0 and 30000 ms.
Ping Delay
1000
The amount of time, in milliseconds, between each ping after a Start Ping button tap.
9-20