Registry Key Default Value Description
min, L2 is max length".
Code39CheckDigitTransmission 0x0
Enable transmission of the check
digit.
Code39StartStopTransmission 0x0
Enables transmission of start/stop
characters.
Code39AcceptedStartCharacter 0x2
Selects start character, where 1 =
'$', 2 = '*', and 3 = '$' and '*'.
Code39FullASCIIConversion 0x0
Enables extended character set
through the use of control
characters, where 0 = disabled
and 1 = enabled (extended spec).
Code39UDSI "B1"
User-defined symbology identifier.
Range is 0-4 characters.
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 128] - Code 128 Symbology
Configuration
Code128Activation 0x1
Enables the standard Code 128
symbology.
ISBT128Activation 0x0
Enables the International Society
of Blood Transfusion's variant of
Code 128.
GS1-128Activation 0x1
Enables the GS1 (formerly EAN)
variant of Code 128.
UnconventionalGS1-128 0x1
Unconventional decoding mode
bitfield, where bit 0 = allow decode
of double FNC1, bit 1 = FNC2
append disabled, bit 2 = FNC4
ASCII extensions disabled.
Code128ReadingRange 0x1
Enables Vesta algorithm decoding
for better read range.
Code128CodeMark 0x44
A single character inserted before
the bar code data to indicate the
symbology.
83 A700x Product Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Vocollect A700 Series and is the answer not in the manual?

Honeywell Vocollect A700 Series Specifications

General IconGeneral
BrandHoneywell
ModelVocollect A700 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals