96 Xenon/Granit User Guide
Locked Link Mode - Single Scanner
If you link a scanner to a base using the Locked Link Mode, other scanners are
blocked from being linked if they are inadvertently placed into the base. If you do
place a different scanner into a base, it will charge the scanner, but the scanner will
not be linked.
To use a different scanner, you need to unlink the original scanner by scanning the
Unlink Scanner bar code. (See Scanner Modes,page 95.)
Open Link Mode - Single Scanner
When newly shipped or defaulted to factory settings, a scanner is not linked to a
base. A link is established when the scanner is placed into a base. When in Open
Link Mode, a new link is established when a new scanner is placed in the base.
Each time a scanner is placed into a base, the scanner becomes linked to the base
and the old scanner is unlinked.
Unlink the Scanner
If a base has a scanner linked to it, that scanner must be unlinked before a new
scanner can be linked. Once the previous scanner is unlinked, it will no longer com-
municate with the base. To unlink the scanner from a base, scan the Unlink Scan-
ner bar code below.
Locked Link Mode
(Single Scanner)
* Open Link Mode
(Single Scanner)
Unlink Scanner

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g