68 Xenon/Granit User Guide
To put the scanner in multiple scanner mode, scan the bar code below. Once you
scan this bar code, the scanner is unlinked from the base or Access Point and must
either be placed into the base, or you must scan the Access Point linking bar code
in order to relink.
Scanner Name
You may assign a name to each scanner you are using for identification purposes.
For example, you may want to have a unique identifier for a scanner that is receiv-
ing imaging commands sent from the base or Access Point.
The default name is in the format “ScannerName_Model_SN_XXXXXXXXXX” If you
have more than one scanner linked to a base, and they all have the same name, the
first scanner linked to the base receives commands. When renaming a series of
scanners with identical names, unlink all except one of the scanners from the base.
Perform the rename operation using either the bar codes on page 69, or by send-
ing the serial command :ScannerName:BT_NAMNewName. where ScannerName
is the current name of the scanner, and NewName is the new name for the scanner.
If you wish to change the names of additional scanners, link them one at a time and
repeat the :ScannerName:BT_NAMNewName. command for each scanner.
To rename scanners with sequential, numeric names, scan the bar codes below.
Scan the Reset code after each name change and wait for the scanner to relink to
the base or Access Point before scanning a bar code to rename the next scanner.
Multiple Scanner Operation
0001
0002
0003
0004

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g