76 Xenon/Granit User Guide
Trigger Reconnect Mode
Note: This setting is only supported by Granit 1981i/1911i.
Trigger Reconnect allows you to control the relink process rather than having it
occur automatically. First scan Auto Reconnect Off (page 75), then scan Trigger
Reconnect On. The scanner begins the relink process when the trigger is pulled.
Default = Trigger Reconnect On.
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scanner
tries to form a connection with a base or an Access Point. During the connection
setup process, the scanner transmits in order to search for and connect to a base
or an Access Point. In order to prevent continuous transmissions that could inter-
Event Auto Reconnect On Auto Reconnect Off
Scanner out of range Relink occurs automatically. If
maximum number of link attempts
is unsuccessful, then the scanner
must be relinked by either pulling
the trigger, placing the scanner in
the base, or scanning the Access
Point linking bar code. (See
Maximum Link Attempts on page
76.)
The scanner is relinked by
pulling the trigger, or scanning
the Access Point linking bar
code.
Base or Access point reset
(firmware upgrade or power
cycle)
Scanner behaves as if out of range. No attempt to relink made
while base or Access Point is
powered off. Trigger must be
pulled to initiate relinking.
Scanner power down due to
Power Time-Out Timer
setting
Trigger must be pulled, Access Point linking bar code must be
scanned, or the scanner must be placed in the base unit to relink.
(Note: scanner relinks on power up, but powers on due to one of the
above actions.)
Scanner reset due to
firmware upgrade
Relink occurs automatically.
Scanner reset due to battery
change
Relink occurs automatically.
Scanner placed in different
base unit
Relink to new base occurs automatically.
*Trigger Reconnect On
Trigger Reconnect Off

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g