Example
See
Also
Programming
the
Logic
Analyzer
To
copy
commands
to
\system\program
Programming
the
logic
analyzer
over
an
NFS
mount
with
a
file
Suppose macrune 1 is configured as a state analyzer. To clear the format and
trigger set-ups of macrune
1,
first create
the
following command
file.
File clear.txt:
:SELECT
1
:MACHINEl:SFORMAT:REMOVE ALL
:MACHINEl:STRIGGER:CLEAR ALL
The first command selects
the
analyzer to receive programming commands.
The second command clears
the
format set-up.
The
third
command clears
the
trigger set-up.
Now copy the
file
to
the
logic analyzer.
At
the
MS-DOS prompt, enter:
copy
clear.txt
L:\system\program
If
your computer runs
the
UNIX
operating system, you might use the
cp
command.
In
an
MS
Windows environment, you can
use
File Manager.
The Programmer's Guide for
your
logic analyzer for a detailed description of
the commands.
The
Progranuner's Guide can
be
ordered
from your
HP
Sales
Office.