Table 10-1 Numeric Codes and Text Messages (continued)
Control panel message Description Recommended action
3. If the error still persists, replace the
system board.
2205-Interface error during MEBx execution MEBx operation experienced a hardware error
during communication with ME.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the
system board.
2211-Memory not congured correctly for
proper MEBx execution.
SODIMM1 or XMM1 is not installed. Make sure there is a memory module in the
black SODIMM1 socket and that it is properly
seated.
2212-USB Key Provisioning failure writing to
device
USB device used for USB key provisioning will
not allow BIOS to update provision le properly.
1. Try a dierent USB key device for
provisioning.
2. If the error persists, update to the latest
BIOS version and ME rmware version.
3. If the error still persists, replace the
system board.
2217-ME Firmware Version request failure ME rmware is not properly responding to BIOS
query for version information.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME rmware version.
3. If the error still persists, replace the
system board.
2218-ME Firmware Version should be updated ME rmware must be updated to match current
functionality contained in the system BIOS.
1. Update to the latest ME rmware version.
2. If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version.
3. If the error still persists, replace the
system board.
2219-USB Key Provisioning le has invalid
header identier
Provisioning le contained on the USB key has
been corrupted or is not a valid version for the
current ME rmware.
1. Recreate the provisioning le using third
party management console software.
2. If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME rmware version.
3. If the error still persists, replace the
system board.
2220-USB Key Provisioning le has mismatch
version
Provisioning le contained on the USB key is not
a valid version for the current ME rmware.
1. Reboot the computer.
2. If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME rmware version.
3. If the error still persists, replace the
system board.
2230-General error during MEBx execution Error occurred during MEBx execution which
fails into the “General” grouping. Status
information displayed along with the error
provides further clarity into the failure. MEBx
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME rmware version.
POST Numeric Codes and Text Messages 107