EasyManua.ls Logo

HP 3PAR StoreServ 7000 - Cage; Format of Possible Cage Exception Messages; Cage Example 1; Cage Suggested Action 1

HP 3PAR StoreServ 7000
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
cage
Displays drive cage conditions that are not optimal and reports exceptions if any of the following
do not have normal states:
Ports
SFP signal levels (RX power low and TX failure)
Power supplies
Cage firmware (is not current)
Reports if a servicecage operation has been started and has not ended.
Cages are supported for hardware platform
Format of Possible cage Exception Messages
Cage cage:<cageid> "Missing A loop" (or "Missing B loop")
Cage cage:<cageid>,mag:<magpos> "Magazine is <MAGSTATE>"
Cage cage:<cageid> "Power supply <X>'s fan is <FANSTATE>"
Cage cage:<cageid> "Power supply <X> is <PSSTATE>" (Degraded, Failed, Not_Present)
Cage cage:<cageid> "Power supply <X>'s AC state is <PSSTATE>"
Cage cage:<cageid> "Cage is in "servicing" mode (Hot-Plug LED may be illuminated)"
Cage cage:<cageid> "Firmware is not current"
Cage cage:<cageid> "Cage type <Model> is not supported on this platform"
Cage cage:<cageid> "Missing both A and B loops"
Cage cage:<cageid> "Cage state information is unavailable"
cage Example 1
Component -Summary Description- Qty
Cage Cages missing A loop 1
Component -Identifier- -Detailed Description--
Cage cage:1 Missing A loop
cage Suggested Action 1
Check the connection/path to the SFP in the cage and the level of signal the SFP is receiving. An
RX Power reading below 100 µW signals the RX Power Low condition; typical readings are between
300 and 400 µW. Helpful CLI commands are showcage -d and showcage -sfp ddm.
At least two connections are expected for drive cages, and this exception is flagged if that is not
the case.
cli% showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model FormFactor
1 cage1 1:0:1 1 0:0:1 1 8 21-23 402e 402e DCS2 SFF
-----------Cage detail info for cage1 ---------
Position: ---
Interface Board Info Card0 Card1
Firmware_status Current Current
Product_Rev 402e 402e
State(self,partner) OK,OK OK,OK
VendorId,ProductId HP,DCS2 HP,DCS2
Master_CPU Yes No
SAS_Addr 50050CC1178EA0BE 50050CC1178E6BBE
Link_Speed(DP1,DP2) 6.0Gbps,Unknown 6.0Gbps,Unknown
PS PSState ACState DCState Fan State Fan0_Speed Fan1_Speed