EasyManua.ls Logo

HP 3PAR StoreServ 7000 - Cage Example 3; Cage Suggested Action 3; Cage Example 4

HP 3PAR StoreServ 7000
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
cage Example 3
Component -Identifier- --------------Detailed Description----------------
Cage cage:1 Cage is in "servicing" mode (Hot-Plug LED may be illuminated)
cage Suggested Action 3
When a servicecage operation is started, it puts the targeted cage into servicing mode, and
routing I/O through another path. When the service action is finished, the servicecage endfc
command should be issued to return the cage to normal status. This checkhealth exception is
reported if the I/O module cage is in servicing mode. If a maintenance activity is currently occurring
on the drive cage, this condition can be ignored.
NOTE: The primary path can be seen by an asterisk (*) in showpd's Ports columns.
cli% showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model FormFactor
1 cage1 --- 1 0:0:1 1 8 20-23 402e - DCS2 SFF
-----------Cage detail info for cage1 ---------
Position: ---
Interface Board Info Card0 Card1
Firmware_status Current -
Product_Rev 402e -
State(self,partner) OK,OK -,-
VendorID,ProductID HP,DCS2 -,-
Master_CPU Yes -
SAS_Addr 50050CC1178EA0BE -
Link_Speed(DP1,DP2) 6.0Gbps,Unknown -,-
PS PSState ACState DCState Fan State Fan0_Speed Fan1_Speed
ps0 OK OK OK OK Low Low
ps1 OK OK OK OK Low Low
-------------Drive Info------------------ ----PortA---- ----PortB----
Drive DeviceName State Temp(C) LoopState LoopState
0:0 5000c500720387e0 Normal 20 - OK
0:1 5000c50072039188 Normal 21 - OK
0:2 5000c500720387b0 Normal 21 - OK
0:3 5000c500720395b4 Normal 21 - OK
0:4 5000c50072036fbc Normal 21 - OK
0:5 5000c50072039fc0 Normal 21 - OK
0:6 5000c50072037250 Normal 21 - OK
0:7 5000c5005737cc0c Normal 23 - OK
cli% showpd -s
Id CagePos Type --State-- ------Detailed State------
20 1:0:0 FC degraded disabled_A_port,servicing
21 1:0:1 FC degraded disabled_A_port,servicing
22 1:0:2 FC degraded disabled_A_port,servicing
23 1:0:3 FC degraded disabled_A_port,servicing
cli% showpd -p -cg 1
---Size(MB)--- ----Ports----
Id CagePos Type Speed(K) State Total Free A B
20 1:0:0 FC 10 degraded 139520 119808 0:0:2- 1:0:2*
21 1:0:1 FC 10 degraded 139520 122112 0:0:2- 1:0:2*
22 1:0:2 FC 10 degraded 139520 119552 0:0:2- 1:0:2*
23 1:0:3 FC 10 degraded 139520 122368 0:0:2- 1:0:2*
cage Example 4
SComponent ---------Summary Description--------- Qty
Cage Cages not on current firmware 1
Troubleshooting Storage System Components 41