ps0 OK OK OK OK Low Low
ps1 Failed Failed Failed OK Low Low
-------------Drive Info-------------- --PortA-- --PortB--
Drive DeviceName State Temp(C) LoopState LoopState
0:0 5000c500720387e0 Normal 21 OK OK
1:0 5000c50072039188 Normal 21 OK OK
2:0 5000c500720387b0 Normal 21 OK OK
3:0 5000c500720395b4 Normal 21 OK OK
4:0 5000c50072036fbc Normal 21 OK OK
5:0 5000c50072039fc0 Normal 21 OK OK
6:0 5000c50072037250 Normal 22 OK OK
7:0 5000c5005737cc0c Normal 23 OK OK
cage Example 2
Component -------------Summary Description-------------- Qty
Cage Degraded or failed cage power supplies 2
Cage Degraded or failed cage AC power 1
Component -Identifier- ------------Detailed Description------------
Cage cage:1 Power supply 0 is Failed
Cage cage:1 Power supply 0's AC state is Failed
Cage cage:1 Power supply 2 is Off
cage Suggested Action 2
A cage power supply or power supply fan is failed, is missing input AC power, or the switch is
turned OFF. The showcage -d cageX and showalert commands provide more detail.
cli% showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model FormFactor
1 cage1 1:0:1 1 0:0:1 1 8 21-23 402e 402e DCS2 SFF
-----------Cage detail info for cage1 ---------
Position: ---
Interface Board Info Card0 Card1
Firmware_status Current Current
Product_Rev 402e 402e
State(self,partner) OK,OK OK,OK
VendorId,ProductId HP,DCS2 HP,DCS2
Master_CPU Yes No
SAS_Addr 50050CC1178EA0BE 50050CC1178E6BBE
Link_Speed(DP1,DP2) 6.0Gbps,Unknown 6.0Gbps,Unknown
PS PSState ACState DCState Fan State Fan0_Speed Fan1_Speed
ps0 OK OK OK OK Low Low
ps1 Failed Failed Failed OK Low Low
-------------Drive Info-------------- --PortA-- --PortB--
Drive DeviceName State Temp(C) LoopState LoopState
0:0 5000c500720387e0 Normal 21 OK OK
1:0 5000c50072039188 Normal 21 OK OK
2:0 5000c500720387b0 Normal 21 OK OK
3:0 5000c500720395b4 Normal 21 OK OK
4:0 5000c50072036fbc Normal 21 OK OK
5:0 5000c50072039fc0 Normal 21 OK OK
6:0 5000c50072037250 Normal 22 OK OK
7:0 5000c5005737cc0c Normal 23 OK OK
40 Troubleshooting