EasyManua.ls Logo

HP 3PAR StoreServ 7000 - Installing HP 3 PAR OS Files

HP 3PAR StoreServ 7000
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX Power uW 476 158 562 125 631
RX Power uW 98 15 1000 10 1258
port Example 2
Component -Summary Description- Qty
Port Missing SFPs 1
Component -Identifier- -Detailed Description--
Port port:0:3:1 SFP is missing
port Suggested Action 2
FC node-ports that normally contain SFPs will report an error if the SFP has been removed. The
condition can be checked using the showport -sfp command. In this example, the SFP in 1:1:1
has been removed from the adapter:
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:1:1 OK HP-F 8.5 No No No Yes
0:1:2 OK HP-F 8.5 No No Yes Yes
1:1:1 - - - - - - -
1:1:2 OK HP-F 8.5 No No Yes Yes
port Example 3
cli% checkhealth -detail port
Checking port
Component -Summary Description- Qty
Port Offline ports 1
-----------------------------------
1 total 1
Component -Identifier- --Detailed Description--
Port port:0:1:2 is offline
-----------------------------------
1 total
port Suggested Action 3
Check the state of the port with showport. If a port is offline, it was deliberately put in that state
using the controlport offline command. Offline ports might be restored using controlport
rst.
cli% showport
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState
...
0:1:1 target ready 2FF70002AC00006E 20110002AC00006E host FC - 1:1:1 none
0:1:2 target offline 2FF70002AC00006E 20120002AC00006E free FC - 1:1:2 none
...
port Example 4
Component ------------Summary Description------------ Qty
Port Ports with mismatched mode and type 1
Component -Identifier- ------Detailed Description-------
Port port:2:0:3 Mismatched mode and type
Troubleshooting Storage System Components 61