due to a service action, such as hardware or software upgrades, these exceptions can be ignored
until that action has finished and the node is online.
In this example, LD 35, with a name of R1.usr.3, is owned (Own) by nodes 3/2/0/1, respectively,
and the primary/secondary physical paths to the drives (chunklets) in this LD are from nodes 3
and 2, respectively. However, the FC path (Port B) from node 3 to PD 91 is failed/missing, so
node 2 is performing the I/O to PD 91. When the path from node 3 to cage 3 gets fixed (N:S:P
3:0:4 in this example), this condition should disappear.
cli% showld
Id Name RAID -Detailed_State- Own SizeMB UsedMB Use Lgct LgId WThru MapV
35 R1.usr.3 1 normal 3/2/0/1 256 256 V 0 --- N Y
cli% showldch R1.usr.3
Ldch Row Set PdPos Pdid
Pdch State Usage Media Sp From To 0 0 0 2:2:3 63
0 normal ld valid N --- --- 1 0 0 3:8:3 91
0 normal ld valid N --- ---
cli% showpd 91 63
----Size(MB)---- ----Ports----
Id CagePos Type Speed(K) State Total Free A B
63 2:2:3 FC 10 normal 139520 124416 2:0:3* 3:0:3
91 3:8:3 FC 10 degraded 139520 124416 2:0:4* -----
cli% showpd -s -failed -degraded
Id CagePos Type -State-- ---------------Detailed_State----------
91 3:8:3 FC degraded missing_B_port,loop_failure
cli% showcage
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
2 cage2 2:0:3 0 3:0:3 0 24 29-42 2.37 2.37 DC2 n/a
3 cage3 2:0:4 0 ----- 0 32 28-40 2.37 2.37 DC2 n/a
Normal condition (after fixing):
cli% showpd 91 63
----Size(MB)---- ----Ports----
Id CagePos Type Speed(K) State Total Free A B
63 2:2:3 FC 10 normal 139520 124416 2:0:3* 3:0:3
91 3:8:3 FC 10 normal 139520 124416 2:0:4 3:0:4*
port
Checks for the following port connection issues:
Ports in unacceptable states
Mismatches in type and mode, such as hosts connected to initiator ports, or host and Remote
Copy over Fibre Channel (RCFC) ports configured on the same FC adapter
Degraded SFPs and those with low power; perform this check only if this FC Adapter type
uses SFPs
Ports listed as hosts in "showhost" that are not ready or not configured as host
Host ports or systesm with too many initiators connected
Format of Possible port Exception Messages
Port port:<nsp> "Port mode is in <mode> state"
Port port:<nsp> "is offline"
Port port:<nsp> "Mismatched mode and type"
Port port:<nsp> "Port is <state>"
Port port:<nsp> "SFP is missing"
Port port:<nsp> SFP is <state>" (degraded or failed)
Port port:<nsp> "SFP is disabled"
Port port:<nsp> "Receiver Power Low: Check FC Cable"