EasyManua.ls Logo

HP 3PAR StoreServ 7000 - Node Suggested Action 1; Node Example 2; Node Suggested Action 2

HP 3PAR StoreServ 7000
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Node node:1 Power supply 0 detailed state is AC Failed
Node node:1 Power supply 0 AC state is Failed
Node node:1 Power supply 0 DC state is Failed
node Suggested Action 1
Examine the states of the power supplies with commands such as shownode, shownode -s,
shownode -ps, and the like. Turn on or replace the failed power supply.
NOTE: In the example below, the battery state is considered Degraded because the power
supply is Failed; this is normal.
cli% shownode
Control Data Cache
Node --Name--- -State-- Master InCluster ---LED--- Mem(MB) Mem(MB) Available(%)
0 1001356-0 Degraded Yes Yes AmberBlnk 2048 8192 100
1 1001356-1 Degraded No Yes AmberBlnk 2048 8192 100
cli% shownode -s
Node -State-- -Detailed_State-
0 Degraded PS 1 Failed
1 Degraded PS 0 Failed
cli% shownode -ps
Node PS -Serial- -PSState- FanState ACState DCState -BatState- ChrgLvl(%)
0 0 FFFFFFFF OK OK OK OK OK 100
0 1 FFFFFFFF Failed -- OK Failed Degraded 100
1 0 FFFFFFFF Failed -- Failed Failed Degraded 100
1 1 FFFFFFFF OK OK OK OK OK 100
node Example 2
Component -Identifier- ---------Detailed Description------------
Node node:3 Power supply 1 battery is Failed
node Suggested Action 2
Examine the state of the battery and power supplies with commands such as shownode, shownode
-s, shownode -ps, showbattery (and showbattery with -d, -s, -log), and the like. Turn
on, fix, or replace the battery backup unit.
cli% shownode
Control Data Cache
Node --Name--- -State-- Master InCluster ---LED--- Mem(MB) Mem(MB) Available(%)
2 1001356-2 OK No Yes GreenBlnk 2048 8192 100
3 1001356-3 Degraded No Yes AmberBlnk 2048 8192 100
cli% shownode -s
Node -State-- -Detailed_State-
2 OK OK
3 Degraded PS 1 Degraded
cli% shownode -ps
Node PS -Serial- -PSState- FanState ACState DCState -BatState- ChrgLvl(%)
2 0 FFFFFFFF OK OK OK OK OK 100
2 1 FFFFFFFF OK OK OK OK OK 100
3 0 FFFFFFFF OK OK OK OK OK 100
3 1 FFFFFFFF Degraded OK OK OK Failed 0
cli% showbattery
Node PS Bat Serial -State-- ChrgLvl(%) -ExpDate-- Expired Testing
3 0 0 100A300B OK 100 07/01/2011 No No
3 1 0 12345310 Failed 0 04/07/2011 No No