Safety precautions for the fusing-lamp emitter
Disregard of the safety precautions or improper operation of the infrared emitter can lead to injuries
and mat
erial damage.
The IR heating device should be operated only by specialists or trained personnel.
The operator of the system should compile specific instructions for personnel training.
The safety and functional reliability of the IR heating device are guaranteed only if you are using
original acce
ssories and spare parts from HP.
After an emitter break, a dangerous voltage may be exposed to contact by the heating spiral.
The reflector side should not be cleaned.
Transport and handling of the fusing-lamp emitter
Transport the IR emitter, in the packaging provided, to the place of installation.
CAUTION: If the IR emitter must be transported without its packaging, wear linen gloves.
F
ingerprints on the quartz tube will cause devitrification, which leads to radiation losses and
mechanical failure.
Always carry the emitter with both hands. Carry it so that the cross-section faces up, to avoid
bending and breaking.
Grip the emitter only by the ceramic edges, and not by the pinches. Do not touch the glass unless
y
ou are wearing gloves.
Avoid any pressure on the flat base.
When installing IR emitters
HP recommends that you wear protective goggles when installing or replacing emitters, to protect
y
ourself from broken glass that you may come into contact with.
The safety and functional reliability of the IR heating device are guaranteed only when using original
acce
ssories and spare parts from HP.
After an emitter break, a dangerous voltage may be exposed to contact by the heating spiral.
The reflector side should not be cleaned.
After installation, the bottom glasses of the IR emitter must be cleaned of any soiling or perspiration.
S
ee
Clean the fusing-lamp glasses on page 190.
1. Turn the assembly upside down and unscrew the four screws of the exterior glass frame.
2. Carefully remove the frame of the exterior glass.
CAUTION: When you remove the frame, the glass may stick to it. Take care that the glass does not
f
all out of the frame as you pick it up.
Replace the fusing lamp 261