8. Pull the left-hand filter out of its enclosure.
9. Dispose of the old filters according to local regulations.
10. Vacuum the area with an explosion-protected vacuum cleaner.
11. Insert the two new filters. Take care to insert the filter correctly: the arrow on the side of the filter
should point towards the interior of the processing station.
12. Close the cover, pushing it back. At the same time, tighten the door locking screws by hand. Make
sure they are completely tightened.
Replace the vacuum-pump filter
The following sections provide details for this topic.
Prepare for replacement
The following steps provide the complete procedure for this topic.
1. Locate the new vacuum-pump filters, which are provided in the Processing-station maintenance kit.
2. Ensure that the processing station is not in use.
3. You are recommended to wear goggles, gloves, and mask.
Replace the vacuum-pump filter
The following steps provide the complete procedure for this topic.
1. Start the replacement from the front panel, when requested.
2. If material cartridges are placed on the front of the processing station, remove them.
Replace the vacuum-pump filter 299