Cabling 115
Item
Description
2
Connect the power cable from the 10SFF Express Bay backplane to
the 2SFF Express Bay backplane.*
3
Connect the mini-SAS cable from the 10SFF Express Bay backplane
to Port 1 on the controller (HPE Smart Array P440ar Controller
shown).
4
Connect the 2SFF Express bay data cable from 2SFF Express Bay
backplane to Port 3 on the HPE Express Bay Bridge Card.*
5–6
Connect the 10SFF Express bay data cable from 10SFF Express Bay
backplane to Ports 1 and 2 on the HPE Express Bay Bridge Card.
*If the 2SFF Express Bay Enablement option is not installed, then this cable is not required.
HPE Smart Array P440ar controller cabling
Connect the SAS/SATA cables to the backplane and Smart Array controller. Install the SAS/SATA cables
according to their labels as Port 1 or Port 2. These labels are on the cables and their connections.