Hardware options installation 62
I
CAUTION: To prevent improper cooling and thermal damage, do not operate the server or
the enclosure unless all drive and device bays are populated with either a component or a
blank.
14. Install the high-performance fans ("High-performance fan option" on page 33).
15. Install the NVMe drives ("Installing the NVMe drives" on page 55).
16. Install the access panel (on page 22).
17. Install the server into the rack.
18. Connect each power cord to the server.
19. Connect each power cord to the power source.
20. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED
changes from amber to green.
4LFF Universal Media Bay option
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause ESD.
1. Back up all server data.
2. Power down the server (on page 21).
3. Do one of the following:
o Extend the server from the rack (on page 21).
o Remove the server from the rack (on page 22).
4. Remove the access panel (on page 22).
5. Remove the bay blanks.