HP Smart Array errors 141
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that power supply number <power supply number>
was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id=24731
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> was <inserted /
removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24732
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a SAS link PHY error has been detected. The
PHY error threshold has been exceeded for PHY number <PHY number> located on
expander number <expander number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24733
Severity: Informational
Log message: The external Smart Array controllers located in the MSA chassis labeled
as <chassis label> are now redundant.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24734
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that no redundant array controller is installed.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24735
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled
as <chassis label> are not redundant because they are different models.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24736
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled
as <chassis label> are not redundant because an inter-controller link could not
be established.