EasyManua.ls Logo

HP ProLiant Gen9 - Page 286

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Microsoft Windows Event ID and SNMP traps 286
cpqDaSpareBay
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”
NT Event ID: 1064 (Hex)0xc4350428 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in slot %4, port %5, bay %6 with serial number “%7”, has a new status of
%2.
SNMP Trap: cpqDa5PhyDrvStatusChange - 3029 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status.
User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaPhyDrvStatus
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1065 (Hex)0xc4350429 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Status Change.
Log Message: The array accelerator board attached to the array controller in slot %4 has a new status of %2.
SNMP Trap: cpqDa5AccelStatusChange - 3025 in CPQIDA.MIB
Symptom: Accelerator Board Status Change. This trap indicates that the agent has detected a change in the
status of an array accelerator cache board. The current status is represented by the variable
cpqDaAccelStatus.
User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator
board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrSlot

Table of Contents

Related product manuals