Microsoft Windows Event ID and SNMP traps  314 
Symptom: External Tape Drive Status Change. This trap indicates that the agent has detected a change in the 
status of an External Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status. 
User Action: If the tape is failed or is offline, check the tape and all connections. 
Supporting SNMP Trap Data: 
•  sysName 
•  cpqHoTrapFlags 
•  cpqFcTapeDriveCntlrIndex 
•  cpqFcTapeDriveScsiBus 
•  cpqFcTapeDriveScsiTarget 
•  cpqFcTapeDriveScsiLun 
•  cpqFcTapeDriveModel 
•  cpqFcTapeDriveFWRev 
•  cpqFcTapeDriveSerialNumber 
•  cpqFcTapeDriveLocation 
•  cpqFcTapeDriveStatus 
Supporting SNMP Trap Description: “Status is now [cpqFcTapeDriveStatus] for a tape drive.” 
NT Event ID: 1194 (Hex)0x843504aa (cpqstmsg.dll) 
Log Severity: Warning (2) 
Event Title: External Tape Drive Cleaning Required. 
Log Message: The tape drive at location “%4” requires cleaning. 
SNMP Trap: cpqExtTapeDriveCleaningRequired - 16024 in CPQFCA.MIB 
Symptom: External Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to 
have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned. 
Supporting SNMP Trap Data: 
•  sysName 
•  cpqHoTrapFlags 
•  cpqFcTapeDriveCntlrIndex 
•  cpqFcTapeDriveScsiBus 
•  cpqFcTapeDriveScsiTarget 
•  cpqFcTapeDriveScsiLun 
•  cpqFcTapeDriveModel 
•  cpqFcTapeDriveFWRev 
•  cpqFcTapeDriveSerialNumber 
•  cpqFcTapeDriveLocation 
Supporting SNMP Trap Description: “Cleaning is needed for tape drive.” 
NT Event ID: 1195 (Hex)0x843504ab (cpqstmsg.dll)