Microsoft Windows Event ID and SNMP traps 332
Log Severity: Warning (2)
Event Title: Storage System Connection Status Change.
Log Message: The %7 storage system connected to %5 of the controller in %4 has a new connection status
of %6. (Connection status values: 1=other, 2=notSupported, 3=connected, 4=notConnected)
SNMP Trap: cpqSsConnectionStatusChange - 8032 in CPQSTSYS.MIB
Symptom: The agent has detected a change in the connection status of a storage system. The variable
cpqSSboxConnectionStatus indicates the current connection status.
User Action: If the connection status is disconnected, take action to restore the connection between the HBA
and the storage system.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxCntlrHwLocation
cpqSsBoxCntlrIndex
cpqSsBoxBusIndex
cpqSsBoxVendor
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxConnectionStatus
cpqSsBoxLocationString
cpqSsBoxTargetSasAddress
cpqSsBoxLocalManageIpAddress
Supporting SNMP Trap Description: "Storage system connection status changed to %d."
NT Event ID: 1226 (Hex)0x843504ca (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SAS/SATA Physical Drive SSD Wear Status Change.
Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear status of
%7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold,
5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqSasPhyDrvSSDWearStatusChange - 5026 in CPQSCSI.MIB
Symptom: The agent has detected a change in the SSD wear status of a SAS or SATA physical drive. The
variable cpqSasPhyDrvSSDWearStatus indicates the current SSD wear status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.