Microsoft Windows Event ID and SNMP traps 353
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight keyboard cable disconnected.”
NT Event ID: 1114 (Hex)0x8435045a (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A processor has crossed the threshold of allowable corrected errors. The processor should be
replaced.
SNMP Trap: cpqSeCpuThresholdPassed - 1005 in CPQSTDEQ.MIB
Symptom: This trap is sent when an internal processor error threshold has been passed on a particular
processor, causing it to become degraded. This trap is sent when cpqSeCpuThreshPassed transitions from
false to true.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSeCpuSlot
cpqSeCpuSocketNumber
cpqSeCpuSpeed
cpqSeCpuExtSpeed
cpqSeCpuCacheSize
Supporting SNMP Trap Description: “CPU internal corrected errors have passed a set threshold.”
SNMP Trap: cpqSeCpuStatusChange - 1006 in CPQSTDEQ.MIB
Symptom: This trap is sent when CPU status changed. CPU can be brought down to Stop state and removed
from O.S Active set or Brought back to Running state and made member of O.S Active set.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSeCpuUnitIndex
cpqSeCpuSlot
cpqSeCpuName
cpqSeCpuSpeed
cpqSeCpuStep
cpqSeCpuStatus
cpqSeCpuExtSpeed
cpqSeCpuSocketNumber
cpqSeCpuHwLocation