Microsoft Windows Event ID and SNMP traps 356
NT Event ID: 1123 (Hex)0x84350463 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during server
startup.
SNMP Trap: cpqHe3PostError - 6027 in CPQHLTH.MIB
Symptom: One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server
restart process.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Errors occurred during server restart.”
NT Event ID: 1124 (Hex)0x84350464 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Fault Tolerant Power Supply Sub-system is in a degraded state. Restore power or replace
the failed power supply.
SNMP Trap: cpqHe4FltTolPowerSupplyDegraded - 6049 in CPQHLTH.MIB
Symptom: The fault tolerant power supply condition has been set to degraded for the specified chassis and
bay location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolPowerSupplyChassis
cpqHeFltTolPowerSupplyBay
cpqHeFltTolPowerSupplyStatus
cpqHeFltTolPowerSupplyModel
cpqHeFltTolPowerSupplySerialNumber
cpqHeFltTolPowerSupplyAutoRev
cpqHeFltTolPowerSupplyFirmwareRev
cpqHeFltTolPowerSupplySparePartNum
cpqSiServerSystemId
Supporting SNMP Trap Description: “The Power Supply is Degraded on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status
[cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num
[cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”
NT Event ID: 1125 (Hex)0xc4350465 (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: The Fault Tolerant Power Supply Sub-system is in a failed state. Restore power or replace the
failed power supply.