Microsoft Windows Event ID and SNMP traps 366
User Action: Shut down the enclosure and possibly the rack as soon as possible. Be sure that all fans are
working properly and that air flow in the rack has not been blocked.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTempLocation
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature sensor
in rack [cpqRackName] has been set to failed.”
NT Event ID: 1148 (Hex)0x8435047c (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Enclosure Overheating
Log Message: This trap indicates that an enclosure temperature sensor has been tripped indicating a possible
overheat condition.
SNMP Trap: cpqRackEnclosureTempDegraded - 22006 in CPQRACK.MIB
Symptom: The enclosure temperature status has been set to degraded. This trap indicates that an enclosure
temperature sensor has been tripped, indicating a possible overheat condition.
User Action: Shut down the enclosure and possibly the rack as soon as possible. Be sure that all fans are
working properly and that air flow in the rack has not been blocked.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTempLocation
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature sensor
in rack [cpqRackName] has been set to degraded.”
NT Event ID: 1149 (Hex)0x4435047d (cpqsvmsg.dll)