HP ProLiant server errors 91
1804-Slot X Drive Array - Cache Module critical error...
Action: Replace Cache Module (Controller is disabled until this problem is resolved).
Audible Beeps: None
Possible Cause: The Cache Module has a critical error.
Action: Replace the Cache Module.
1806-Slot X Drive Array - Cache Module flash memory is not installed;...
IMPORTANT: Unsupported Configuration: Cache Module functionality is limited.
Action: Install the flash memory to remove these limitations.
Audible Beeps: None
Possible Cause: The Cache Module flash memory is not installed.
Action: Install the flash memory.
1807-Slot X Drive Array - Cache Module incompatible with this controller.
IMPORTANT: Access to all storage has been disabled.
Action: Replace the Cache Module to re-enable all storage.
Audible Beeps: None
Possible Cause: The Cache Module is incompatible with the controller.
Action: Replace the Cache Module.
1808-Slot X Drive Array - Cache Module critical error
IMPORTANT: Access to all storage has been disabled.
Action: Replace the Cache Module to re-enable all storage.
Audible Beeps: None
Possible Cause: The Cache Module has a critical error.
Action: Replace the Cache Module.
1809- Slot X Encryption Failure- Communication issue prevents drive keys from being
retrieved...
...Encrypted logical drives are offline. System may not boot.
Action: To troubleshoot, see the iLO Key Manager page.
1810- Slot X Encryption Failure- Master Key is incorrect on or not retrieved from
Remote Key Manager...
...Encrypted logical drives may be offline. System may not boot.
Action: Correct the problem on the Key Manager GUI.
1811- Slot X Encryption Failure- Drive Keys not retrieved from the Remote Key
Manager...
...Dependent encrypted logical drives are offline. System may not boot.