EasyManua.ls Logo

HP ProLiant ML370 Generation 3 - Redundant Hot-Plug Power Supply; Hot-Plug Power Supply Bays

HP ProLiant ML370 Generation 3
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing Hardware Options
HP ProLiant ML370 Generation 3 Server Setup and Installation Guide 3-67
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: d-ch03 Installing Hardware Options.doc
Codename: Dizzy Devil Part Number: 281992-002 Last Saved On: 12/3/02 12:45 PM
Redundant Hot-Plug Power Supply
The server supports a second hot-plug power supply to provide redundant power to
the system in the event of a failure in the primary power supply. You can install or
replace a second hot-plug power supply without powering down the server.
CAUTION: If only one power supply is installed, do not remove the power supply
unless the server has been powered down. Failing to power down before removing a
power supply in a non-redundant configuration could cause data loss.
To install a second hot-plug power supply:
1. Locate the secondary hot-plug power supply bay.
Figure 3-57: Hot-plug power supply bays
Table 3-13: Hot-Plug Power Supply Bays
Item Description
1 Secondary (redundant) hot-plug power supply blank
2 Primary hot-plug power supply

Table of Contents

Related product manuals