EasyManua.ls Logo

HP ProLiant ML370 Generation 3 - External SCSI Hard Drives

HP ProLiant ML370 Generation 3
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server Cabling
6-12 HP ProLiant ML370 Generation 3 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: g-ch06 Server Cabling.doc
Codename: Dizzy Devil Part Number: 281992-002 Last Saved On: 12/3/02 2:15 PM
To determine server cabling needs for specific applications:
3. Determine whether cabling needs are for primary storage (hard drive) or for
secondary storage (tape drive or CD-ROM drive).
4. Identify the controller type.
5. Identify the drive type to be used:
Ultra2, or Ultra3 SCSI hard drive
CD-ROM storage drive
DAT or DLT tape drive
Universal Hot-Plug Tape Drive
After you finish cabling external storage options, use the SmartStart CD to run the
following applications:
RBSU—enables you to configure new hardware in the system.
Array configuration utilities—enable you to configure and manage drive arrays
for SCSI hard drives.
IMPORTANT: Use configuration utilities after installing any non-hot-plug option in the
server.
External SCSI Hard Drives
Follow these general guidelines when adding external SCSI hard drives:
A maximum of 14 SCSI devices per port can be supported externally (only six
internally).
Each SCSI drive must have a unique ID.
CAUTION: All data on the hard drive can be lost when you migrate from a non-array
controller. Back up all data before migrating drives to an intelligent array
configuration.