Installing Hardware Options
3-22 HP ProLiant ML370 Generation 3 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: d-ch03 Installing Hardware Options.doc
Codename: Dizzy Devil Part Number: 281992-002 Last Saved On: 12/3/02 12:45 PM
Installing Hardware Options
This chapter includes step-by-step instructions for installing:
Processors and PPMs
Memory
Hot-plug SCSI hard drives
Removable media devices
Optional internal two-bay hot-plug SCSI drive cage
Redundant hot-plug fans
Redundant hot-plug power supply
Expansion boards
For additional instructions for installing and configuring hardware options, refer to
the documentation that ships with each option kit.
For information on obtaining hardware options and upgrades for the server, refer to
www.hp.com/products/servers/platforms/
Processors and PPMs
CAUTION: The processor, heatsink, and retaining clip comprise a single assembly.
Separating the processor from the heatsink causes thermal instability and damage to
the server.
IMPORTANT: If you must replace a failed processor or processors, clear the status log in
RBSU after powering up the server. Refer to the maintenance and service guide for
replacement instructions or contact your authorized service provider.
Installing a Second Processor and PPM
The server supports the installation of a second Intel Xeon processor for enhanced
performance. Processor option kits available for the server include an Intel Xeon
processor with heatsink and a processor power module (PPM).