For more information on how to review the Onboard Administrator SHOW ALL output for warnings or
possible failures, see the HPE BladeSystem c-Class Enclosure Troubleshooting Guide on the Hewlett
Packard Enterprise website (http://www.hpe.com/support/BladeSystem_Enclosure_TSG_en).
2. To verify the status and diagnostics for the blade, access Device bays > Host > Status tab.
3. Review the IML tab for possible server hardware events that require action.
4. Review possible interconnect link state issues on the Status tab > Port Mapping Information.
Any Green indicator on a Port indicates that a link is available at the transportation layer. This means
that a NIC or a possible SAN connection should be established and that the midplane signals are
transferred correctly from the server to the interconnect device.
5. The Table view tab on this screen displays the Port Status indicator as Green for all connections.
For any ports that are not green or that are failed ports, review the signal backplane on the server or
the midplane for damage.
For any blade power on issues, review the iLO screen on the Status tab and the Event Log tab on
the ”iLO – Device bay x” page.
6. If all status indicators are green and no warnings, failed, or degraded components exist, then proceed
to the iLO WEB guide (Status Tab > iLO > Web Administration).
7. If the blade is not displayed in the Insight Display on the chassis or within the Onboard Administrator
GUI, then troubleshoot the issue further using the procedures in the HPE BladeSystem c-Class
Enclosure Troubleshooting Guide on the Hewlett Packard Enterprise website (http://www.hpe.com/
support/BladeSystem_Enclosure_TSG_en).
Using the OA CLI
To gather and respond to information obtained by the SHOW ALL command, perform the following
procedure.
Prerequisites
Gather and review health and system information using the OA CLI to troubleshoot the system:
• For systems using OA firmware 3.60 or later, run the SHOW HEALTH CLI command and review the
health status for the entire chassis. The SHOW HEALTH status output is included within the OA SHOW
ALL report as well as the first executed SHOW command.
• Execute the SHOW ALL command from either the OA GUI or the OA CLI as follows:
◦ OA GUI > Enclosure Settings > Configuration Scripts > SHOW ALL
◦ OA CLI > Execute the following CLI command: SHOW ALL
This command executes all OA CLI SHOW commands to provide a detailed report of the enclosure
configuration, status, and inventory available.
Procedure
1. For systems using OA firmware 3.60 and earlier, review the SHOW ENCLOSURE LCD output of the
SHOW ALL report. A display status of "Blinking" indicates a warning condition. Review the data or
remotely review messages on the Insight Display through the OA GUI.
2. For a status overview of the chassis, review the output of the following commands listed in the SHOW
ALL report:
34 Using the OA CLI