5. Remove the server from the rack.
For instructions on how to extend or remove the server from the rack, see the documentation that ships
with the rack rail system.
6. Place the server on a sturdy, level surface.
Remove the air baffle
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers,
or blanks installed. If the server supports hot-plug components, minimize the amount of time the access
panel is open.
To remove the component:
1. Do one of the following:
For tower models, open and remove the tower bezel.
For rack models, if installed, remove the security bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server .
4. Do one of the following:
For tower models, place the server on a flat, level surface with the access panel facing up.
For rack models,
extend the server from the rack.
5. Remove the access panel.
6. Remove the air baffle.
32 Remove the air baffle