CAUTION:
To prevent damage to electrical components, take the appropriate anti-static precautions before
beginning any installation, removal, or replacement procedure. Improper grounding can cause
electrostatic discharge.
For more information on fan numbering and fan population, see "Hot-plug fans."
To remove the component:
Procedure
1. Do one of the following:
For tower models, open and remove the tower bezel.
For rack models, if installed, remove the security bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server .
4. Do one of the following:
For tower models, place the server on a flat, level surface with the access panel facing up.
For rack models, extend the server from the rack.
5. Remove the access panel.
6. Remove the fan module:
a. Press the release latches on the fan module.
b. Lift the fan module from the fan cage.
To replace the component, reverse the removal procedure.
Access panel
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
34 Access panel