7. Install the air baffle.
8. Install the access panel.
9. Do one of the following:
If the server is in a tower configuration, return the server to an upright position.
If the server is in a rack configuration, slide the server into the rack.
10. Connect each power cord to the server .
11. Connect each power cord to the power source.
12. Power up the server.
13. Do one of the following:
For tower models, install the tower bezel.
For rack models, install the security bezel.
DIMMs
IMPORTANT:
This server does not support mixing LRDIMMs and RDIMMs. Attempting to mix any combination of
these DIMMs can cause the server to halt during BIOS initialization.
To identify the DIMM s installed in the server , see "DIMM slots."
1. Do one of the following:
For tower models, open and remove the tower bezel.
For rack models, if installed, remove the security bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server .
4. Do one of the following:
a. For tower models, place the server on a flat, level surface with the access panel facing up.
b. For rack models, extend the server from the rack.
5. Remove the access panel.
6. Remove the air baffle.
7. Remove the DIMM.
50 DIMMs