15. Close the PCI slot retainer cover.
16. Install the fan cage.
17. Install the air baffle.
18. Install the access panel.
19. Do one of the following:
• If the server is in a tower configuration, return the server to an upright position.
• If the server is in a rack configuration, slide the server into the rack.
20. Connect each power cord to the server .
21. Connect each power cord to the power source.
22. Power up the server.
23. Do one of the following:
• For tower models, install the tower bezel.
• For rack models, install the security bezel.
8-LFF drive backplane
To remove the component:
Procedure
1. Back up all server data.
2. Do one of the following:
• For tower models, open and remove the tower bezel.
• For rack models, if installed, remove the security bezel.
3. Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server .
5. Do one of the following:
• For tower models, place the server on a flat, level surface with the access panel facing up.
• For rack models, extend the server from the rack.
6. Remove the access panel.
7. Remove the air baffle.
8-LFF drive backplane 65