4. Install the air baffle.
5. Install the access panel.
6. Do one of the following:
If the server is in a tower configuration, return the server to an upright position.
If the server is in a rack configuration, slide the server into the rack.
7. Connect each power cord to the server .
8. Connect each power cord to the power source.
9. Power up the server.
10. Do one of the following:
For tower models, install the tower bezel.
For rack models, install the security bezel.
Processor
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:
To prevent possible server malfunction and damage to the equipment, multiprocessor configurations
must contain processors with the same part number.
CAUTION:
The heatsink thermal interface media is not reusable and must be replaced if the heatsink is removed
from the processor after it has been installed.
IMPORTANT:
Processor socket 1 must be populated at all times or the server does not function.
To remove the component:
Procedure
1. Do one of the following:
46 Processor