Table 42: File system status and recommended actions
Status Description Recommended Actions
Mounted The file system is up and
running.
None required.
Not Mounted The file system is not up and
running, resulting in the service
sets not starting.
This is expected during upgrades
or during the power on sequence.
If the file system status is
Unmounted at any other time,
reboot the appliance or couplet.
If this does not resolve issue,
contact Hewlett Packard
Enterprise Support.
Segments On Backup The file system is in a failed over
state and some of the storage is
owned by its failover node.
This may be as intended or as a
result of a failure condition.
Check and resolve any issues
shown in the Events Log. To
failback, run the StoreOnce CLI
command system failback
[specified service set].
Space Over Some or all of the storage
components have reached 90%
capacity utilization.
This may be temporary or
showing that the specified file
system is approaching its
capacity. Check the Events Log
to see whether the file system is
reaching capacity. If so, increase
storage capacity or delete data
from the file system to prevent
backup failure.
Segment Unavailable Some or all of the storage
components have detected a
problem. The file system is set to
read-only mode to prevent further
problems.
This is due to the storage
subsystem unexpectedly going
offline. Check if the storage
subsystem is online and then run
the StoreOnce CLI command
system recover
filesystem. If the issue
persists, contact Hewlett Packard
Enterprise Support.
Table Continued
128 Storage configuration and reporting