Screen elements Description
Sequential Read Cache Hits -
Frontend
The sequential Frontend I/O read cache hit values.
Sequential Reads - Frontend The sequential Frontend I/O read values.
Sequential Writes - Frontend The sequential Frontend I/O write values.
Sequential MB Reads - Frontend The sequential Frontend reads throughput in MB/s for the LDEV.
Sequential MB Writes - Frontend The sequential Frontend writes throughput in MB/s for the LDEV.
Sequential Write Cache Hits -
Frontend
The sequential Frontend write cache hit values in per second.
SS ID The identification number of the subsystem.
SLPR The SLPR group ID.
NOTE: SLPR does not exist in the P9500/XP7 disk arrays.
So, the SLPR group ID is displayed only for the XP disk
arrays.
Target:LUN The LUN associated with the given LDEV.
Vol. Group The volume group identification name if the device is associated
with a volume group. PA reports volume groups from LVM (an
HPE brand) and VXVM (a Veritas brand).
Attribute Indicates a volume is of ALU (Administrative Logical Unit)/ SLU
(Subsidiary Logical Unit) type.
Resource Group Represents the number of resource groups that are part of the
selected VSM.
NOTE:
The E-LDEV, Ext-LUN, E-Port(s), E-Seq, Jnl Group, and Vol. Group are available for selection
only if they are configured in the selected XP or XP7 disk array.
The following metrics are not applicable for the XP/XP7 continuous access journal pool LDEVs.
NA is displayed:
Response Time Metric category: Maximum Write Response and Average Write Response
Frontend IO Metric category: Random Write Cache Hits, Random Writes, Sequential Write
Cache Hits, and Sequential Writes
Frontend MB Metric category: Random MB Writes and Sequential MB Writes